Toepler pump

From Wikipedia, the free encyclopedia
Jump to navigation Jump to search
File:Toeplersche Quecksilberluftpumpe.png
Toepler Pump diagram

A Toepler pump is a form of mercury piston pump,[1][2] invented by August Toepler in 1850.

Operation

[edit | edit source]

The principle is illustrated in the diagram. When reservoir G is lowered, bulb B and tube T are filled with gas from the enclosure being evacuated (through tube A). When G is raised, mercury rises in tube F and cuts off the gas in B and T at C. This gas is then forced through the mercury in tube D into the atmosphere. The end of tube D is bent upward at E to facilitate collection of gas (or vapor). By alternately raising G, a pumping action results. Clearly tubes F and D must be long enough to support mercury columns corresponding to atmospheric pressure (76 cm at sea level). Instead of using mercury to provide a valving action at C, it is possible to use a glass float valve.

References

[edit | edit source]
  1. ^ Lua error in Module:Citation/CS1/Configuration at line 2172: attempt to index field '?' (a nil value).
  2. ^ Lua error in Module:Citation/CS1/Configuration at line 2172: attempt to index field '?' (a nil value).

Further reading

[edit | edit source]
  • Andrew Guthrie (1963). Vacuum Technology; Wiley; New York and London.
  • R. W. Cahn (2001). The Coming of Materials Science. Pergamon. University of Michigan. p405.