Maximum experimental safe gap

From Wikipedia, the free encyclopedia
Jump to navigation Jump to search

Maximum experimental safe gap (MESG) is a standardized measurement of how easily a gas flame will pass through a narrow gap bordered by heat-absorbing metal. MESG is used to classify flammable gases for the design and/or selection of electrical equipment in hazardous areas, and flame arrestor devices.[1] The National Electrical Code classifies Class I hazardous locations into different groups depending on the respective MESG's of gases in the area.[2]

Examples

[edit | edit source]
NEC Class I Group and Gas MESG[2]
NEC Class I Group Gas MESG Example Gas
Group A 0.25 mm Acetylene
Group B ≤0.45 mm (Except acetylene) Hydrogen
Group C 0.45 mm < x ≤ 0.75 mm Ethylene
Group D > 0.75 mm Propane

References

[edit | edit source]
  1. ^ Lua error in Module:Citation/CS1/Configuration at line 2172: attempt to index field '?' (a nil value).
  2. ^ a b [1][dead link] Class I: Flammable gases, vapors or liquids

http://site.ul.com/global/documents/offerings/services/hazardouslocations/CI_groups.pdf[permanent dead link]